Omode
SCPI Commands
TRIGger:SEQuence:IMMediate:SOURce:OMODe
- class OmodeCls[source]
Omode commands group definition. 2 total commands, 1 Subgroups, 1 group commands
- get(arg_0: TriggerOperMode) TriggerOperMode [source]
# SCPI: TRIGger[:SEQuence][:IMMediate]:SOURce:OMODe value: enums.TriggerOperMode = driver.trigger.sequence.immediate.source.omode.get(arg_0 = enums.TriggerOperMode.CC)
Sets or queries the operation mode to trigger on for trigger source ‘operation mode’ See Figure ‘Overview of trigger IO system’.
- param arg_0
CC | CV | CR | SINK | PROTection CC If respective channel operation mode is detected in CC mode, corresponding trigger-out parameters are triggered. CV If respective channel operation mode is detected in CV mode, corresponding trigger-out parameters are triggered. CR If respective channel operation mode is detected in CR mode, corresponding trigger-out parameters are triggered. SINK If respective channel operation mode is detected in sink mode, corresponding trigger-out parameters are triggered. PROTection If respective channel operation mode is detected in protection mode (OVP, OCP, OPP OTP) , corresponding trigger-out parameters are triggered.
- return
arg_0: CC | CV | CR | SINK | PROTection CC If respective channel operation mode is detected in CC mode, corresponding trigger-out parameters are triggered. CV If respective channel operation mode is detected in CV mode, corresponding trigger-out parameters are triggered. CR If respective channel operation mode is detected in CR mode, corresponding trigger-out parameters are triggered. SINK If respective channel operation mode is detected in sink mode, corresponding trigger-out parameters are triggered. PROTection If respective channel operation mode is detected in protection mode (OVP, OCP, OPP OTP) , corresponding trigger-out parameters are triggered.
- set(arg_0: TriggerOperMode) None [source]
# SCPI: TRIGger[:SEQuence][:IMMediate]:SOURce:OMODe driver.trigger.sequence.immediate.source.omode.set(arg_0 = enums.TriggerOperMode.CC)
Sets or queries the operation mode to trigger on for trigger source ‘operation mode’ See Figure ‘Overview of trigger IO system’.
- param arg_0
CC | CV | CR | SINK | PROTection CC If respective channel operation mode is detected in CC mode, corresponding trigger-out parameters are triggered. CV If respective channel operation mode is detected in CV mode, corresponding trigger-out parameters are triggered. CR If respective channel operation mode is detected in CR mode, corresponding trigger-out parameters are triggered. SINK If respective channel operation mode is detected in sink mode, corresponding trigger-out parameters are triggered. PROTection If respective channel operation mode is detected in protection mode (OVP, OCP, OPP OTP) , corresponding trigger-out parameters are triggered.